| Pneumatic control valve | Compressed air used to operate actuators, cylinders, or control devices | Tube fittings, threaded ports, valve body joints, actuator seals, or exhaust port | External connection leak or internal valve leakage | Hissing sound, slow actuator movement, pressure loss, or a compressor that cycles too often | Loose fitting, damaged tubing, worn O-ring, contaminated spool, or excessive pressure | Isolate the air supply, depressurize the circuit, and apply leak-detection solution to accessible joints | Tighten or replace fittings and tubing; replace damaged seals or service the valve if leakage continues | Medium |
| Tire inflation valve | Compressed air or nitrogen inside a tire | Valve core, valve stem, stem-to-rim seal, or valve cap area | Slow pressure leak | Gradual tire pressure loss, repeated low-pressure warnings, or bubbles around the valve | Loose or damaged valve core, cracked rubber stem, corrosion at the rim, or a missing valve cap | Check the tire when cold and use soapy water around the valve core and stem; bubbles indicate escaping air | Replace the valve core or complete valve stem as appropriate; inflate to the vehicle maker's specified pressure | High |
| Hydraulic valve | Pressurized hydraulic oil or another approved hydraulic fluid | Hose fittings, cartridge seals, valve mounting face, spool, or relief-valve adjustment area | External fluid leak or internal bypass leakage | Visible oil, falling system pressure, slow or drifting movement, heat generation, or an oily surface | Damaged seal, loose connection, scratched sealing surface, hose deterioration, or excessive pressure | Stop the equipment, isolate the hydraulic energy, allow components to cool, and inspect without touching pressurized parts | Depressurize before repair; replace seals, hoses, or fittings with correctly rated parts and clean spilled fluid | Critical |
| Process-air valve | Plant compressed air used for instruments, tools, cleaning, or production processes | Isolation valve stem, flange gasket, threaded connection, drain, regulator, or filter bowl | External air leak or leakage through a closed isolation valve | Continuous hiss, pressure drop downstream, unstable instrument readings, or moisture near a drain | Worn packing, failed gasket, poor thread seal, vibration, corrosion, or an open condensate drain | Follow site isolation procedures and use an approved ultrasonic detector or leak-detection solution where permitted | Repair during a controlled shutdown; replace packing, gaskets, drains, or connections using compatible materials | Medium to High |
| Pressure-relief or safety valve | Compressed air, gas, steam, or liquid depending on the installation | Discharge outlet, seat, spring housing, or connected discharge piping | Unintended discharge or seat leakage | Air escaping from the outlet below the expected set pressure, pressure instability, or repeated valve opening | Debris on the seat, incorrect set pressure, corrosion, damaged spring, or excessive back pressure | Do not block, cap, adjust, or disassemble the valve; verify pressure readings using approved procedures | Remove the system from service when required and have the valve inspected, tested, or replaced by qualified personnel | Critical |
| Vacuum or check valve | Air under vacuum or low positive pressure | Valve seat, diaphragm, threaded joint, hose connection, or gasket | Reverse-flow leakage or loss of vacuum | Vacuum decays while isolated, pump runs continuously, or the system fails to hold pressure | Worn diaphragm, dirt on the seat, incorrect flow direction, cracked hose, or poor sealing | Isolate the equipment and compare pressure or vacuum decay on each side of the valve | Clean or replace the valve and inspect hoses, gaskets, and installation direction | Medium |